Went out to put away all … Had some things come up so I just left everything as it was. If volt age is lower than 1 1 volt s, it is recommended that the battery be placed on a charger until it is fully charged. 1. 8. Usually a wiring problem. Been bit, schwintek motor short circuit. Usually a wiring problem. Motor short circuit: Motor or wiring to motor has shorted out. Power Connection: 12V DC input. Check the 12 volt fuse box for blown fuses, and replace any if necessary. It Schwintek In-Wall Slide-Out Motor - Removing and Replacing - (With Motor Notch on Seal) - YouTube Turns out it was a chaffed wire causing the intermittent problem. What have I done so far in an attempt to solve the problem? Page 4 Checking Fuses The Schwintek In-Wall™ Slide requires a minimum of 30 amp fuse. 8 Hall signal not present: Encoder is not providing a signal. Hi Everyone, I have a couple questions I hope someone can answer for me. Rev: 11.21.2014 Page 5 IN-WALL™ Slide-out Owner's Manual Controller Overview (C-2 Version) Motor 1 Connector Motor 2 Connector Power Connection Controller Version Fig. This should be a Schwintek system, click HERE and it will give you some troubleshooting and allow you to see how that room is set up. It is generally located in a compartment that is separate from the motors themselves, so disconnecting motors is simple. Motor short circuit: Motor or wiring to motor has shorted out. 8. Hall signal not present: Encoder is not providing a signal. ... Low Voltage The Schwintek In-Wall™ Slide Controller is capable of operating the room with as little as 8 volts. Hall signal not present: Encoder is not providing a signal. Motor short circuit: Motor or wiring to motor has shorted out. I've read the 'Schwintek In-Wall™ Slideout System Operation and Service Manual' cover to cover, and watched a handful of YouTube videos on the subject, without finding a solution to my particular problem. But at these lower voltages the amperage requirement is greater. ... 6 Motor short circuit: Motor or wiring to motor has shorted out. The Schwintek Inwall Slide Controller is cap able of operating the room with as little as 8 volt s. But at these lower volt ages the amperage requirement is greater . Usually a wiring problem. Does only 1 side of the room move a … Check volt age at the controller . Usually a wiring problem. The plastic wire way in the metal part of the motor is smaller than the black cap so it cut the red wire. Hall signal not present: Encoder is not providing a signal. 6 Motor short circuit: Motor or wiring to motor has shorted out. Under the kitchen counter I have a Schwintek 13398-b Dual Motor Synchronous Velocity Slide Out Controller and it is flashing an The motors on the slide are located about 3/4 of the way up the wall of the slide. But at these lower voltages the amperage requirement is greater. ... Low Voltage The Schwintek In-Wall™ Slide Controller is capable of operating the room with as little as 8 volts. IN-WALL™ S - OWNER'S MANUAL Rev: 11.21.2014 Page 1 IN-WALL™ Slide-out Owner's Manual TABLE OF CONTENTS System and Safety Information Safety Information Prior to Operation Operation Extending Slide-out Room Retracting Slide-out Room Troubleshooting Controller Overview (B Version) Controller Overview (C-2 Version) Electronic Manual Override Extend and Retract Switch … 8. The Schwintek Inwall Room Slide has a separate moto r to operate each side of the room. If only one corner is not working it sounds like it can possible be an issue with the motor. 5 Switch Connection Status LEDs: 2 LEDs, 1 green and 1 red, are provided to indicate current controller status and faults. There is a controller on the Schwintek slide system that has connectors to the motors. Mode Button: Used to engage the electronic manual override. I have the lube for the slides and that was on my list to do. Well, I opened it up today and the main slide was a little sluggish.