Cleaned debris from capillary bulb and mount. Nickle Cap and Bulb. condition. Safety System. If the “reset switch” you’re referring to is the high limit reset, you likely need a new thermostat. 5. Computer: A. Pitco has been an industry leader in design, research, and delivering new ideas for frying in commercial foodservice operations. Manual Reset. If the SCBS high temperature limit switch continues to trip, have the appliance inspected by an Authorized Professional. Any other ideas? The high temperature limit switch will stop the appliance from functioning if the oil temperature in the cook tank reaches an unsafe temperature. Computer display shows "OFF" and cannot be turned "ON" A. Switch circuit breaker OFF and ON again to try to reset computer, if this does not remedy the problem, replace computer. When the roll out switch or hi-limit trips, it interrupts the 24 VAC supply to the ignition module. Do not operate the fryer in this condition as there is no over temperature protection. Robertshaw Fryer Hi Limit Safety part number 5225-11J (5225-119). With almost 300 comments on our Repairing Commercial Fryers post, we figured it was time to get a video out there to better illustrate how easy it can be to fix a fryer yourself. Bulb Dimensions 5/16" x 3-5/8". Cleaned bottom of fryer of 2in thick crud. Turn the computer OFF and back ON again to reset the computer. If no reset, jump the two wires and see if the fryer will now light. Then cycled fryer at highest setpoint to see if it trips prematurely. Time: ending soonest; Time: newly listed; Price + postage: lowest first; Price + postage: highest first; Distance: nearest first The reset switch must be pressed and released in order to reset the Ignition Control Modules and the com-puter turned back ON again for further use of the fryer. If defective, replace. If the temp is not being reached that could be a high limit issue, a thermostat calibration issue, etc. Told them to make sure it’s off then pull the drain valve. If so, the high limit is defective, assuming the fryer is not over temperature. Pitco gas fryers operation, and maintenance manual 45c+, 35c+ (41 pages) Fryer Pitco E14B Parts Catalog. The reason I am asking is because from all that I have read from the service manual is that the burners turn off when temp is reached. Is this a recent issue? Filter System: The high limit is designed to cut off gas supply if the temperature exceeds 450 degrees (and that’s a … Replacement for numbers: Pitco, P5047213, P5047216, Magikitch'n, P5047213, P5047216, Star MFG, 23209, Y3106, AllPoints, 48-1020 × Temperature Limit 450F. In this video, Chris Tavano, walks you through calibrating the thermostat, bypassing the hi-limit, taking out the thermopile, taking out the combination safety gas valve, and other troubleshooting tips for … Pitco SG14R. If present check the reset. Have you pressed the reset button on the high limit? Test oil temperature with a probe to ensure the burners are not overheating the fryer oil. When the controller calls for heat, it does not receive a 24 VAC HFB. In order to make the computer recognize that the Hi Limit has reset it must be turned OFF. The Hi Limit is an automatic reset type switch. The SCBS high limit switch is now reset and ready for startup. A. Allowr the oil to cool, the Hi Limit will reset itself. They say every morning they have to reset the fryer high limit. Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers. In the event that the high temperature limit has tripped, please refer to the following procedure to reset the switch. Length of Capillary 60".